Flexibility of Application
Siemens IEC Sentron Series molded case circuit breakers
may be used for circuit protection in individual enclosures,
switchboards, lighting and power panel boards as well
as in motor control centers.
The IEC Sentron Series circuit breakers protect cables,
wiring, busbars, motors, transformers as well as plant
components and consumers from thermal-overload and short-circuits.
Trip Free Mechanism
By design the Siemens Sentron series circuit breakers
use a trip-free mechanism which open the circuit breaker
contacts under overload and short circuit conditions,
even if the breaker handle is held in the ON position.
IEC Rated
Siemens Sentron Series circuit breakers have
been tested and qualified to the rugged requirements
set out in IEC 947-2 requirements.
Quick-make, Quick-break Mechanism
This type of mechanism minimizes arcing during operation
as well as preventing the contacts from being “teased”
into the “ON” position.
Front-Adjustable Magnetic Trip
On the 250A frame and above, adjustment buttons are
provided to set the instantaneous trip setting in event
of a short circuit. Any current surge above the trip
setting produces a magnetic field which instantly actuates
the trip mechanism and opens the breaker.
Thermal-trip
This provides protection against sustained overloads.
A bi-metallic element in each conductor path reacts
time-wise in inverse proportion to the current. If a
circuit is overloaded, heat resulting from excessive
current flow cause the bi-metal to bend, actuating the
trip mechanism to open the breaker.
Push-to-Trip
Periodic tripping for maintenance purposes are obtained
by using the “Push-to-Trip” button on all Sentron Series
circuit breakers.
Contacts
All contacts are alloy materials designed to give above
normal life expectancy during in service use.
ARC-Chutes
Arc chutes are designed to confine, divide and extinguish
an arc each time that the breaker contacts interrupt
a short circuit. The arc chute therefore must dissipate
the arcs that are caused when the circuit breaker interrupts
current flow. It contains a stack of U-shaped steel
plates held together by insulating material. The steel
plates divide the arc and cools the gases generated
by the arc.
| Type |
Ampere Rating Range at
50oC Ambient Temperature |
Icu (380/415Vac) |
EFC3M
EFF3M |
15-125A |
35
65 |
FFC3M
FFF3M |
70-250A |
35
65 |
JFC3M
JFF3M |
300-400A |
40
65 |
LFC3M
LFF3M |
450-600A |
40
65 |
LMFC3M
LMFF3M |
700-800A |
40
65 |
NFC3M
NFF3M |
900-1200 |
40
65 |
|